1.two.two Warning Labels Warning Labels Indicating You should cautiously read through this manual prior to use machine. The following labels really are a. Don't location the unit on a sloped area. Usually the out there when the program device may well slide, leading to individual damage or maybe the product works Using the cell malfunction.

Cookie penting untuk memfungsikan situs dengan semestinya. Untuk meningkatkan pengalaman Anda, kami menggunakan cookie untuk mengingat depth login Anda dan menyediakan login aman, mengumpulkan statistik untuk mengoptimalkan fungsionalitas situs, dan menyediakan konten yang disesuaikan dengan minat Anda.

Get a whole and extended watch in the anatomical structure by means of panoramic imaging coupled with velocity indicator and ahead/backward scan capacity generating scanning less difficult, smoother and much more controllable.

This manual might referring to info protected by copyright or patents and isn't going to Express any license beneath the patent rights or copyright of Mindray, or of Other individuals. Web page 9: Assertion

Cut off cable ties connecting the principle unit within the Show by diagonal slicing pliers, and then pull out the corresponding cable plugs.

Mindray’s new technology of black & white ultrasound process, DP-50 Expert, is provided with State-of-the-art imaging technologies letting further penetration and more quickly graphic acquisition with higher resolution.

The chapter supplies the strategy to confirm most important perform and performance of product. This is only used for reference, not preventive execution. Functionality checking and testing of the aspect shall be performed by Mindray company engineers as well as consumer collectively. Webpage sixty six: Basic Examination

Find out much better diagnostic information as a result of prolonged check out of the anatomical framework on all convex probes.

Permits usage of a number of scanned angles to type a single image, resulting in Increased distinction resolution and enhanced visualization

Operate: On the back-close of the leading board, a Particular monitor IC is utilised to observe sign voltages  and clock battery electrical power which have been offered to the main board by the key unit box electric power supply module.

Soon after thriving link, the freshly additional network printer title are going to be revealed during the printer driver checklist. Observe: Prior to join the network printer, make sure the ultrasound system plus the printer are in exactly the same network area, as well as the community is Doing the job normally. The IP handle as well as server name should be legitimate, e.g. Webpage 47 DICOM Placing  Enter the AE Title of your ultrasound system, port and PDU in accordance with the genuine condition, after which you can click on [Alright] to exit the monitor.

Discover improved diagnostic information and facts by extended check out on the anatomical construction on all linear probes

Effectiveness Examination five.5.one Test Procedure Resolution Detection depth Geometric Place Precision Blackout region exam Document the exam images five.5.2 Take a look at Written content The graphic applied here is just for reference, follow the picture influence in the true Take note: condition. Requirements: Exhibit: set the contrast and brightness within the medical software value (or perhaps the default standing) Procedure natural environment: dark home, simulating the scientific application ecosystem. Website page seventy six In issue the transverse resolution tests targets are horizontally displayed, document the small length of two targets that can be Obviously acknowledged. Repeat the Procedure higher than to the transverse resolution tests targets at other depths. As revealed in determine underneath. Axial resolution ... Webpage 77 When using the convex probe, keep the transverse resolution tests targets to notice: be shown near the midline. When using a linear probe with steer function, usually do not turn on the steer operate when conduct the transverse resolution exam. Zoom within the location exactly where the targets Situated if vital. The diameter in the concentrate on point at a certain depth is equal on the transverse resolution for the depth. Web page 78 five.

Right after replacing the CPU module, key file have to be generated Again according to the new MAC handle and prepared Dp50rb into HDD in the equipment. Or else, the configuration perform in the product are going to be dropped. Following eliminating the CPU module, Remove panhead screws with washers (12 M3X6) fixed on the key device box, you will take from the board. Page 118 Determine eight-29 Disassemble the User interface Assembly (one) Maintain the higher edge of user interface assembly, and open up the control panel. Figure 8-thirty Disassemble the Control Panel Assembly (2) Right after taking away a person countersunk head self-tapping screw PT3X10 fixed to the control panel and acquire out the plug of your keyboard and the main device connecting cables, you could potentially remove the user interface assembly.

A wise new shape, Improved mobility and handy Procedure make DP-fifty like minded for all clinical configurations.